The Labtech M500T Multiparameter Water Quality Analyzer is a cutting-edge item which sets demands which may be brand-new the industry of water quality analysis. This technique revolutionary is advanced built to deliver accurate and precise proportions of various parameters in real-time which makes it a tool great professionals utilized in organizations like wastewater treatment aquatic research environmental monitoring and so many more. The Labtech M500T is an item this is works that are multipurpose at monitoring parameters being water numerous including pH conductivity dissolved atmosphere temperature and turbidity. Its advanced level sensors are becoming sensitive and painful and so can determine additionally small variations of these parameters allowing one to recognize dilemmas work potential is corrective they become major issues. Among the list of choices which are the majority are key come with the Labtech M500T is its system user-friendly assists it is user-friendly additionally if you should be maybe not well-versed in water quality analysis. The equipment comes insurance firms a large high-resolution display giving you clear and step-by-step readings of all of the parameters being supervised in addition to an easy intuitive menu system allowing anyone to navigate through the various functions and settings with convenience. Just one more thing this is exceptional the Labtech M500T is its construction robust and materials which can make sure that it could withstand possibly the many conditions that are challenging environmental. The item is housed in a challenging IP67-rated enclosure that protects it from dust dirt and water making it ideal for present in harsh outside environments. The Labtech M500T typically versatile in relation to power choices. It could probably turned out to be running on four AA batteries offering you the freedom to position it to anywhere anytime make use of. Rather it may be connected with AC power when longer runtime is needed
Features
pH
* 1-6 points calibration with Standard Recognition
* Selectable pH buffer groups including DIN NIST USA MERK JIS GB
* Support for pH standard group customization
* Automatic electrode diagnosis with pH slope and offset display
Ion
* 1-6 points calibration
* Selectable measurement unit including μg/L mg/L g/L mmol/L pX ppm etc
* Multi-measurement modes are supported including Direct Reading mode Standard Addition mode Sample Addition mode and GRAN mode
* Over 10 methods are built-in including F- Cl- Br- I- NO3- BF4- NH4+ K+ Na+ Ca2+ Cu2+ Pb2+ Ag+ and etc
user-defined method is supported
Conductivity
* 1-5 points calibration with Standard Recognition
* Settable parameters including cell constant reference temperature 5/10/15/18/20/25°C temperature compensation coefficient and TDS factor
* Temperature compensation type none linear pure water
DO
* Support for air-saturated water or zero oxygen calibration
* Auto barometric pressure compensation
* Manual Salinity Factor Correction
* Selectable pressure unit including kPa mbar Torr Atm
Model No | M500T | |
Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
pH | Range | -2.000 to 20.000 pH |
Resolution | 0.1, 0.01, 0.001pH | |
Accuracy | ±0.002 pH | |
Calibration Points | Up to 6 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
Slope Limit | Yes | |
mV/ORP | Range | -2000.00 to 2000.00 mV |
Resolution | 0.1, 0.01 mV | |
Accuracy | ±0.1 mV or ±0.03% of reading whichever is greater | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1 custom point (relative mV) | |
pX | Range | -2.000 to 20.000 pX |
Resolution | 0.1, 0.01, 0.001 pX | |
Accuracy | ±0.002 pX | |
Calibration Points | Up to 6 | |
ISE | Range | 1E-9 to 9.999E9 |
Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
Resolution | Up to 4 significant digits | |
Accuracy | ±0.3% | |
Calibration Points | Up to 6 | |
Conductivity | Range | 0.000 μS/cm to 2000 mS/cm |
Resolution | 0.001 μS/cm minimum, various with range selection | |
Accuracy | ±0.5% FS | |
Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
Calibration Points | Up to 5 | |
Calibration Reminder | Yes | |
Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm | |
Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
Resolution | 0.01 Ω·cm minimum | |
Accuracy | ±0.5% FS | |
TDS | Range | 0.000~1000 ppt |
Resolution | 0.001 ppm minimum, changed with range | |
Accuracy | ±0.5%FS | |
Salinity | Type | NaCl% |
Range | (0.00~8.00)% | |
Resolution | 0.0001 | |
Accuracy | ±0.1% | |
Dissolved Oxygen Concentration - Polarographic |
Range | 0.00 to 99.99 mg/L |
Resolution | 0.01 mg/L | |
Accuracy | ±0.3mg/L (0.00 to 20.00 mg/L); | |
±10% (20.00 to 99.99 mg/L) | ||
Calibration Reminder | Yes | |
Calibration Points | Air-saturated water or zero point | |
Barometric Compensation | Yes | |
Manual Salinity Factor Correction | Yes | |
% Saturation -Polarographic | Range | (0.0 to 600)% |
Resolution | 0.001 | |
Accuracy | ±2.0% | |
Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Accuracy | ±0.1 | |
Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management | Data Storage | 1000 Groups |
GLP Features | Yes | |
Log Management | Yes | |
Inputs | pH Electrode | BNC(Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs | USB | USB 2.0 flash memory device, PC |
RS 232 | printer, scanner, auto-sampler | |
Display options | Backlight | Yes |
Auto Shutdown | 1~60 min, off | |
Date and Time | Yes | |
General | Power | AC Adapter, 100-240V AC input, DC24V output |
Dimensions, Weight | 220×195×68 mm, 950g (2.09 lb) |
Copyright © Shanghai Labtech Co.,Ltd. All Rights Reserved